Release 10.1A: OpenEdge Data Management:
DataServer for Microsoft SQL Server
Connecting a schema holder
As described previously, connection can take place automatically using the information that you enter when you create a schema holder. In addition, OpenEdge provides the following techniques for connecting to a schema holder:
- Use the Data Dictionary or Data Administration tool. From the main menu, select Database
Connect and supply the schema holder’s physical name and the appropriate connection parameters. You can then select your MS SQL Server database as your working database and connect to it. You cannot use the Utilities
Edit PROGRESS Auto–Connect option to connect to a MS SQL Server data source.
- Use the Progress 4GL
CONNECTstatement (see its reference entry in OpenEdge Development: Progress 4GL Handbook ). ACONNECTstatement must first list the schema holder and related connection parameters, then the MS SQL Server database and related parameters.This command connects a schema holder named
mssholderand MS SQL Server database namedmssdemo:
- Use connection parameters when you start OpenEdge. You can include these parameters on the program item command line or in a parameter file that you specify when you start OpenEdge. A parameter file is portable and easy to maintain. For information on creating a parameter file, see OpenEdge Deployment: Startup Command and Parameter Reference .
You can use combinations of different connection techniques. For example, you can connect the schema holder at startup, then connect to the DataServer using the Progress
CONNECTstatement. If the proper connect information is stored in the schema holder, referencing a table in the MS SQL Server database will cause the DataServer to issue the connect statement automatically. Any combination of connection techniques works, as long as you first connect to the schema holder and then the MSS data source.If you are not updating the schema holder, you can specify the Read-only (
-RO) connection parameter to enhance DataServer performance.If you connect to the schema holder and the MS SQL Server database in a single startup command or connection statement, be sure to specify parameters that affect the schema holder before the Database Name (
-db) parameter. Specify only those parameters that affect the MS SQL Server database connection after the-dbparameter.The following section explains how to connect both a schema holder and an MS SQL Server database when you start up OpenEdge.
|
Copyright © 2005 Progress Software Corporation www.progress.com Voice: (781) 280-4000 Fax: (781) 280-4095 |